logo remede logo remede
La 1ère Communauté Médicale
médecine - pharmacie - odontologie - maïeutique
M'identifier
Mot de passe oublié ?
Je me connecte

Vous n'êtes pas inscrit à l'annuaire des membres ? Inscrivez-vous

T

Preliminary Trial of Augmented reality performed on a regular and a robot-assisted laparoscopic partial nephrectomies - juin 2019

Par Guillaume Teluob - Mise en ligne le 13 juin 2019

Mots clefs : Augmented reality , nephrectomy , urology , radiology

Introduction: Augmented reality (AR) aims at improving the vision of the anatomy in laparoscopy. AR works with regular, robot-assisted, and 3D laparoscopies. It modifies the intraoperative vision to provide the surgeon with effects such as a virtual transparency of the organ, to reveal the organ's inner structures, namely tumors and the major vessels.1–5 AR is a technical challenge and only recently has the first AR software capable of handling soft tissue deformation on a mobile organ been proposed.1 This AR software has been developed by an interdisciplinary research team involving surgeons and computer scientists. The software works by fusing a preoperative MR or CT volume with the laparoscopy video. It is image based; it does not require a special hardware nor the use of artificial markers. It can thus be used easily in any standard laparoscopy-equipped operating room. Its benefits were evaluated in an ex vivo preclinical study for guiding tumor resections with porcine kidneys.2 Performance was measured with the negative margin rate across 59 resected pseudotumors. This was 85.2% with AR guidance and 41.9% without, showing a significant improvement. We present the first two cases of using the AR software1 in laparoscopic partial nephrectomy (PN).

Materials and Methods: Both PN cases concerned the resection of a partly exophytic tumor near the arterial pedicle. The procedures used robot-assisted and regular laparoscopies, respectively. First, we created the preoperative 3D model of the kidney from the CT using the Medical Imaging Interaction Toolkit,6 including the tumor and arterial pedicle. Second, we intraoperatively filmed a checkerboard to calibrate the laparoscope and recorded the surgery video. Third, we postoperatively aligned the preoperative 3D model to a laparoscopy image roughly using a tactile screen. The AR software then automatically refined the alignment and augmented the video by overlaying the kidney with the tumor and the arterial pedicle.

Results: The AR software performed effectively in both cases. The kidney was highly mobilized, but the AR software coped and rendered the expected virtual transparency effect. The kidney was not detected at times because of strong occlusions, but AR always resumed quickly and automatically as soon as the part of the kidney nearby the tumor was sufficiently visible. The display of the inner anatomical structures is customizable, and we found that they were made greatly visible using virtual transparency. Although the tumors were already partly visible outside the organ, AR revealed their internal extent and rich information on the organ's inner anatomy.

Conclusion: These two case studies belong to a first series aiming to show AR feasibility in laparoscopic PN. They show that AR in laparoscopic PN may fruitfully complement endoultrasonography. The latter is the current gold standard but has a substantially higher deployment cost than the AR software.1 Much work remains to be done, including running AR intraoperatively and evaluating on a cohort of patients with representative endophytic and exophytic tumors in PN.

Link:
http://doi.org/10.1089/vid.2019.0004

Document(s) attaché(s) :
doc
article-pdf.pdf
livreslivrescontactspublicationstwitter